CoDAS
https://codas.org.br/journal/codas/article/doi/10.1590/2317-1782/20202019047
CoDAS
Artigo Original

Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss

Análise da percepção da fala com uso de dispositivos de amplificação em indivíduos com malformação de orelha e perda auditiva unilateral

Izabella Lima de Matos; Maria Carolina Ferreira; Maria Fernanda Capoani Garcia Mondelli

Downloads: 0
Views: 913

Abstract

Purpose: To verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). Method: The study included fifteen subjects of both sexes who presented congenital malformation of the middle or outer ear, diagnosed with unilateral conductive or mixed hearing loss, moderate to severe hearing loss, age range between 15 to 25 years and, prescription from a specialist doctor for hearing device fitting. We performed the speech perception assessment without amplification after the hearing aid and softband fitting, with the hearing aid linked to the bone vibrator (conventional) and the softband (band with the bone vibrator). The subjects were evaluated using the Hearing in Noise Test (HINT), in silence and in noise. Results: Seven subjects with unilateral ear malformation were evaluated, 57.1 % had impairment in the right ear and 42.9 % in the left ear. Regarding the type and the level of hearing loss, 71 % of all subjects included in the sample presented moderate conductive hearing loss. The assessment of speech perception was performed during silence, frontal noise, lateral noise and, during three specifics situations: no amplification, with conventional hearing aid and with the softband. The results with the amplification devices were positive in all evaluated conditions. Conclusion: Evaluated subjects presented improvement in speech perception, in silence, frontal noise and lateral noise situations, regardless of the type of amplification; however, the difference was not statistically significant.

Keywords

Hearing aids; Congenital abnormalities; Bone conduction; Speech perception; Unilateral hearing loss

Resumo

Objetivo: Verificar a percepção da fala de indivíduos com malformação de orelha e perda auditiva unilateral utilizando dois tipos de amplificação: amplificação sonora individual (AASI) convencional e softband (faixa com vibrador ósseo). Método: Foram selecionados 15 indivíduos, de ambos os sexos, com malformação congênita de orelha externa e/ou orelha média, diagnóstico de perda auditiva unilateral do tipo condutiva ou mista de grau moderado a severo, idade entre 15 e 25 anos, e encaminhamento para amplificação realizado pelo médico otorrinolaringologista. Após a adaptação com AASI e softband, foi realizada avaliação da percepção da fala sem uso da amplificação, com AASI acoplado ao arco e vibrador ósseo (convencional) e com uso do softband (faixa com vibrador). Os indivíduos foram avaliados por meio do Hearing in Noise Test (HINT) nas condições de silêncio e de ruído. Resultados: Foram avaliados sete indivíduos com malformação de orelha unilateral, sendo 57,1% na orelha direita e 42,9% na orelha esquerda. Quanto ao tipo e grau da perda, 71, 4% da amostra possuía perda auditiva condutiva moderada. No teste de percepção de fala na condição de silêncio, ruído frontal e ruído lateral, em três situações: sem amplificação, com o uso do AASI convencional e com o uso do softband, os resultados com uso de dispositivos de amplificação apresentaram-se melhores em todas as condições. Conclusão: Osindivíduos apresentaram melhora sutil, porém não significativa, na percepção de fala tanto em situações de silêncio, ruído frontal e lateral independentemente do tipo de amplificação

Palavras-chave

Auxiliares de audição; Anormalidades congênitas; Condução óssea; Percepção da fala; Perda auditiva unilateral

Referências

1 Dell'Aringa AHB, Castiquini EAT. Adaptação do Aparelho de Amplificação Sonora Individual por Via Óssea em Crianças Portadoras de Malformação de Orelha Externa e Média. Int Arch Otorhinolaryngol. 2005;9(2):310-6. https://doi.org/10.5935/1808-8694.20130063 [ Links ]

2 Paccola ECM, Fernandes JC, Mondelli MFCG. Amplification by bone conduction in congenital malformations: patient benefits and satisfaction. Braz J Otorhinolaryngol. 2013;79(3):359-65. https://doi.org/10.5935/1808-8694.20130063. PMid:23743753 [ Links ]

3 Griffin AM, Poissant SF, Freyman RL. Speech-in-Noise and Quality-of-Life Measures in School-Aged Children With Normal Hearing and With Unilateral Hearing Loss. Ear hear. 2019. https://doi.org/10.1097/AUD.0000000000000667. PMid:30418282 [ Links ]

4 Wie OB, Pripp AH, Tvete O. Unilateral Deafness in Adults: Effects on Communication and Social Interaction. Ann Otol Rhinol Laryngol. 2010;119(11):772-81. PMid:21140638 [ Links ]

5 Kim G, Ju HM, Lee SH, Kim HS, Kwon JA, Seo YJ. Efficacy of Bone-Anchored Hearing Aids in Single-Sided Deafness: A Systematic Review. Otol Neurotol. 2017;38:473-83. https://doi.org/10.1097/MAO.0000000000001359. PMid:28196001 [ Links ]

6 Kulasegaraha J, Burgessb H, Neeffa M, Browna CRS. Comparing audiological outcomes between the Bonebridge and bone conduction hearing aid on a hard test band: Our experience in children with atresia and microtia. Int J Pediatr Otorhinolaryngol 2018;107:176-82. https://doi.org/10.1016/j.ijporl.2018.01.032. PMid:29501302 [ Links ]

7 ANSI S3.13: maximum permissible ambient noise audiometric testing. New York: American National Standards Institute; 1991 [ Links ]

8 Campos PD, Mondelli MFCG, Ferrari DV. Comparação: ganho de inserção obtido em orelha real e simulado. Braz J Otorhinolaryngol. 2011;77(5):555-8. http://dx.doi.org/10.1590/S1808-86942011000500003 [ Links ]

9 Mondelli MFCG, Argentim JP, Rocha AV. Correlação entre percepção de fala e zumbido antes e após o uso de amplificação. Audiol Commun Res. 2016;21:e1649. https://doi.org/10.1590/2317-6431-2015-1649 [ Links ]

10 Thadeu SH, Ferreira MC. The validity of psychological assessment in a selection process in the area of public safety. Rev Iberoam Diagn Ev. 2013;2(36):117-45 [ Links ]

11 Vargas LM, Vargas TM, Cantorani JRH, Gutierrez GL, Pilatti LA. Intellectual disability: origins and trends in concepts from the perspective of social construction. Revista Stricto Sensu. 2016;1(1):12-21. https://doi.org/10.24222/2525-3395.2016v1n1p012 [ Links ]

12 Keith RW. ACPT: Auditory continuous performance test. San Antonio, TX, Psychological Corporation, 1994 [ Links ]

13 Bevilacqua MC, Banhara MR, Costa EA, Vignoly AB, Alvarenga KF. The Brazilian Portuguese Hearing In Noise Test (HINT). Int J Audiol. 2008;47(6):364-5. https://doi.org/10.1080/14992020701870205. PMid:18569110 [ Links ]

14 HINT Pro: Hearing in Noise Test User´s and Service Manual. Mudelen; Bio-logic Systems Corp. 2006 [ Links ]

15 Zhang L, Gao N, Yin Y, Yang L, Xie Y, Chen Y et al. Bone conduction hearing in congenital aural atresia. Eur Arch Otorhinolaryngol. 2016;273(7):1697-703. https://doi.org/10.1007/s00405-015-3727-1. PMid:26205153 [ Links ]

16 Ngui LX, Tang IP. Bonebridge transcutaneous bone conduction implant in children with congenital aural atresia: surgical and audiological outcomes. J Laryngol Otol. 2018;132:693-97. https://doi.org/10.1017/S0022215118001123. PMid:30008276 [ Links ]

17 Mondelli MFCG, dos Santos MM, Jose MR. Percepção da fala no ruído em perda auditiva unilateral. Braz J Otorhinolaryngol. 2016;82(4):427-32. https://doi.org/10.1016/j.bjorl.2015.08.019 [ Links ]

18 Mondelli MFCG, Mariano TCB, Honório HM, de Brito RV. Vibrant soundbridge and bone conduction hearing aid in patients with bilateral malformation of external ear. Int arch otorhinolaryngol. 2016;20:34-8. https://doi.org/10.1055/s-0035-1566155 [ Links ]

19 Henriques MO, Costa MJ. Reconhecimento de sentenças no ruído, em campo livre, em indivíduos com e sem perda auditiva. CEFAC. 2011;3(6):1040-7. https://doi.org/10.1590/S1516-18462011005000024 [ Links ]

20 Wang Y, Fan X, Wang P, Fan Y, Chen X. Hearing improvement with softband and implanted bone-anchored hearing devices and modified implantation surgery in patients with bilateral microtia-atresia. Int J Pediatr Otorhinolaryngol. 2018;104(2018):120-5. https://doi.org/10.1016/j.ijporl.2017.11.010. PMid:29287851 [ Links ]

21 Pittman AL. Bone Conduction Amplification in Children: Stimulation via a Percutaneous Abutment versus a Transcutaneous Softband. Ear Hear. 2019. https://doi.org/10.1097/AUD.0000000000000710. PMid:30870242 [ Links ]

22 Saliba I, Nader ME, Fata FE, Leroux T. Bone anchored hearing aid in single sided deafness: Outcome in right-handed patients. Auris Nasus Larynx. 2011;38:570-6. https://doi.org/10.1016/j.anl.2011.01.008. PMid:21316882 [ Links ]

23 Reinfeldt S, Hakansson B, Taghavi H, Jansson KJF, Eeg-Olofsson M. The bone conduction implant: Clinical results of the first six patients. Int J Audiol. 2015;54:408-16. https://doi.org/10.3109/14992027.2014.996826. PMCID: PMC4487578. PMid:25705995 [ Links ]

24 Snik AF, Mylanus EA, Cremers CW. Speech recognition with the bone-anchored hearing aid determined objectively and subjectively. Ear Nose Throat J. 1994;73(2):115-7. PMid:8168444 [ Links ]

25 Snik AF, Mylanus EA, Cremers CW. The bone-anchored hearing aid compared with conventional hearing aids. Audiologic results and the patients' opinions. Otolaryngol Clin North Am. 1995;28(1):73-83. PMid:7739870 [ Links ]

26 Fuchsmann C, Tringali S, Disant F, Buiret G, Dubreuil C, Froehlich P, et al. Hearing rehabilitation in congenital aural atresia using the bone-anchored hearing aid: audiological and satisfaction results. Acta Oto-Laryngol. 2010;130:1343-51. PMid:20735185. https://doi.org/10.3109/00016489.2010.499879 [ Links ]

27 Lourençone LFM. Prótese Auditiva Ativa cirurgicamente implantável de orelha média para reabilitação auditiva em pacientes com atresia aural congênita bilateral: técnica cirúrgica e resultado audiológico. [Tese] Faculdade de Medicina da Universidade de São Paulo. São Paulo. 2018. https://doi.org/10.11606/T.5.2018.tde-01112018-112945 [ Links ]


Submetido em:
19/02/2019

Aceito em:
17/09/2019

5f35d62f0e88250c2b587299 codas Articles

CoDAS

Share this page
Page Sections